The Solar Ups Inverter an intelligent power frequency pure sine wave inverter. It has an intelligent LCD display that can display various real-time parameters of the inverter operation. It can also be used to set up the inverter. All kinds of parameters can be displayed through LCD display, and you can read daily power generation curves and fault records, which is very important for users. above all
Advantages of Solar Ups Inverter Price: above all
- Solar Ups Inverter Use 100% sufficient transformer and advanced wire design to ensure that the inverter can output at full load. above all
- Solar Ups Inverter has four functions: UPS, voltage regulation, inverter and charging.
- Intelligent LCD screen can display real-time parameters of the inverter and solar controller operation.
- Low Frequency Inverter has the function of fault recording and fault alarm. After the fault occurs, the fault type is directly displayed on the LCD screen, which is convenient for users to eliminate various faults in the operation of the solar energy system. above all
- The solar inverter has a standby mode, and the system will detect the output power. When there is no output, it will automatically enters the standby mode, in which the power consumption is very low.
- With unattended mode, as long as the battery has electricity, the inverter will automatically start. above all
- Using a toroidal transformer, the loss is low and the efficiency is high. above all
- The utility mains power mode and solar energy priority power supply mode can be selected to meet the diversified needs of users.
- You can choose the mains charging mode and PV+ AC charging mode. above all
- Support lithium batteries, lead-acid batteries and other batteries. above all
- The user can adjust various charging parameters and discharge parameters through the display.
- There is a mobile phone APP. You can browse the various parameters of the inverter operation through the mobile phone. ab
-
Solar Ups Inverter Model(TIC-) 2430above all Rated Capacity 3KW (4KVA) Solar Ups Inverter Setting Chinese & English option, Time &Date setting ,Contrast ,lightness, Switch voltage, Grid charge, clear record ,operating parameter, discharge limited setting, Reset .
Work Mode Grid Priority/Battery Priority(optional) LCD Display Internal and External temperature, record query (fault record), System information query Battery Type Lead acid/gel/lithium(optional, factory setting) Charge current Standard:0-30A above all Charge mode Improve charge ,direct charge, float charge AC charge current(A) Standard:0-30A above all AC output voltage(Vac) 110/220/230/240±3% AC output frequency(Hz) 50/60±3% Conversion Efficiency ≥85% Overload 105-120% 30S;120-150% 10S;>150% 5S above all Output Form Pure sine wave Output power factor ≥0.8(>30% Load) above all Wave form distortion ≤3% Switching time ≤4ms above all Overload capacityve al 105-120% 30S;120-150% 10S;>150% 5S Over discharge DC10.5V(12V)/DC21V(24V)/DC42(48V)/DC84V Shut down after alarm Over charge DC16V(12V)/DC32V(21V)/DC64(48V)/DC128V Shut down after alarm lHigh temperature 85° auto shut down after alarm Short circuit Auto shut down Switching time above ≤4mS lCooling method Fan cooling lNoise[dBA] a<60 Operating temperature(℃) -10~ 50 Environment humidity 10% ~ 90%(No condensation) Working Elevation(M) <5000 (>1000m,Derating)